Abstract:Failure analysis and maintenance of ZeeWeed500d UF membrane.Reasonable preventive & corrective measures are proposed following analysis of the scaling problem of UF membrane; and in-depth cause analysis of damage to the membrane elements is made, with solution proposed. The paper also discusses in long paragraphs about check and confirmation of leakage in membrane fiber and damage to membrane elements, identification of the types of membrane failure, and means of restoration. Through research on technologies for cleaning of UF membrane at home and abroad, the paper proposes that ultrasound is an effective means for removal of fouling on membrane surfaces, improvement of membrane flux, and retarding buildup of fouling. 
Key Words:Film Elements; Membrane Fiber; Scaling; Membrane Flux; Permeability  
1  绪论
近年来,北京地区的水资源日趋紧张,燕化公司作为北京市的用水大户,用水量受到北京市的严格限制,水资源缺乏已经成为制约燕化发展的、亟需解决的问题,污水回用工作就成为当务之急。燕化公司于2004年7月建成东区污水回用装置,采用超滤加反渗透组合工艺,将牛口峪污水处理场二级生化处理出水作为原水,经UF/RO处理后回用于锅炉补水,每年可以为化工一厂提供锅炉软化水450万吨。
2  超滤膜的故障分析
Zeeweed500d超滤膜作为超滤系统的核心,其稳定性对整个回用水系统至关重要,每次超滤膜的失效都会引起严重后果甚至系统停车。Zeeweed500d超滤膜系统自投用以来,虽然一直比较平稳,但问题也是经常出现,主要表现在超滤膜的结垢及膜的损坏。
2.1  膜的污堵原理
图1中( a) 所示为新膜(中空纤维超滤膜,聚丙烯材料,膜孔径 0.11μm) 表面的电镜照片,可以清楚地看到膜表面的网状骨架和均匀分布的孔。此时, 膜未受到污染,具有较高的通量。( b) 所示为膜组件运行一段时间,已被污染堵塞后膜表面的电镜照片,从照片中已经看不到膜孔的存在,膜表面粘附的污泥形成了生物膜,并可观察到生物膜上附着生长的短杆菌。此时,膜阻力已较大,膜通量大幅度降低,膜组件需要进行清洗。( c )所示为膜组件污染后,膜孔断面的电镜照片 ,可以清晰地看到在膜孔内吸附沉积的污染物,使得膜孔径减小,降低了过水断面,水流阻力增加。 
 

超滤膜的污堵程度是采用膜透过压 TMP (Trans Membrane Pressure)来衡量的。初始